Fluke 289 Industrial Multimeter Service Kit
Item #: 174655
Manufacturer: Fluke Electronics
Manufacturer Item #: FLUKE 289/IMSK
|
This kit includes all of the items you need to carry out electrical maintenance, accurately, quickly and safely
Features & Applications:
This Fluke 87V industrial multimeter service kit includes all of the items you need to carry out electrical maintenance, accurately, quickly and safely.
This kit includes:
Fluke i400 AC Current Clamp:
The Fluke AC Current Clamp i400 is a single range 400 A ac current clamp with current output via safety shrouded banana plugs. The clamp is compatible with most Fluke multimeters or any other current measurement device that accepts 4mm-shrouded banana plugs and has an AC milliamp range. The division ratio is 1000:1.
Features:
- Companion to your DMM to measure up to 400 A AC
- 1mA/Amp output garantuees easy reading on you meter
- Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
- Specially designed to offer maximum utility in a very compact shape
- Take accurate current readings without breaking the circuit
- Soft non-slippery overmold handle prevents form accidental touching live wiring
- Max. conductor Ø 32 mm
Spec Summary:
| Specifications |
Nominal current range: |
400A |
Continuous current range: |
1 A - 400 A |
Maximum Non-Destructive Current: |
1000 A |
Lowest measurable current: |
1 A |
Basic accuracy: |
2% + 0.06 A
(45-400 Hz)
(% reading + floorspec) |
Usable frequency: |
5 Hz - 20 kHz |
Output levels: |
1 mA/A |
| Safety Specifications |
Safety: |
CAT IV 600 V, CAT III, 1000 V |
Maximum voltage: |
1000 V AC rms from earth to ground,
in compliance with EN61010 |
| Mechanical & General Specifications |
Warranty: |
1 year |
Maximum conductor diameter: |
1.25 in. (32 mm) |
Maximum conductor size
(busbar): |
750 MCM |
Output cable length: |
59 in. (1.5 m) |
Shrouded banana plugs: |
Yes |
Fluke 289 True-RMS Industrial Logging Multimeter:
The Fluke 289 True-RMS Industrial Logging Multimeter is designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. With the ability to log data and review it graphically on-screen, you can solve problems faster and help minimize downtime.
Features:
- Large 50,000 count, ¼ VGA display with white backlight.
- Log multiple sessions or log data continuously for over 200 hours. This is useful for characterizing the performance of a design or for unattended monitoring
- i-info button on board help screens for measurement functions. Unsure about a function? Go to that function and Press the “i” button
- LoZ Volts. Low impedance voltage function prevents false readings due to “ghost voltage.” It is also the recommended mode when testing for absence or presence of live power
- Low Pass Filter for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
- 50 ohm range – useful for measuring and comparing differences in motor winding resistance, low ohm measurements, or other contact resistance. Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current
- Saved measurements allow you to name and recall measurements made in the field
- Real Time Clock – for automatic time stamping of saved readings
- Field upgradeable and expandable meter lets you stay current as new capabilities are added
- Multi-lingual interface
- Min/Max/Average with Time Stamp to record signal fluctuations
- Soft keys, scroll buttons and easy navigation control access to secondary functions. Create custom displays too
- 0.025% Basic DC accuracy
- 100 kHz ac bandwidth
- True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads
- Measure up to 10A (20 A for 30 seconds; 10A continuous)
- 100 mF capacitance range
- Temperature function
- Relative mode to remove test lead resistance from low ohms or capacitance measurements
- Peak capture to record transients as fast as 250 μs
- Premium test leads and alligator clips included
- Optical USB PC communication interface allows for easy PC download to document logged data with FVF software (not included)
- Limited lifetime warranty
- CAT III 1000 V / CAT IV 600 V safety rated
Spec Summary:
| Specifications |
| Voltage DC |
| Accuracy |
0.025 % |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
| Voltage AC |
| Accuracy |
0.4 %(true-rms) |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
| Current DC |
| Accuracy |
0.06 % |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
| Current AC |
| Accuracy |
0.61 %(true-rms) |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
| Temperature (excluding probe) |
| Accuracy |
1.0 % |
| Range and Resolution |
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
|
| Resistance |
| Accuracy |
0.05 % |
| Range and Resolution |
500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
|
| Resistance 10 50 Ω (2 wire connection) |
| Accuracy |
0.15 % + 20 |
| Range and resolution |
50.000 Ω |
|
| Capacitance |
| Accuracy |
1.0 % |
| Range and Resolution |
1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF Ω |
|
| Frequency |
| Accuracy |
0.005% + 1 |
| Range and Resolution |
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
|
| Additional functions/features |
| Multiple on-screen displays |
Yes |
| True-rms AC bandwidth |
100 kHz |
| DBV/dBm |
Yes |
| DC mV resolution |
1 μV |
| Megohm range |
Up to 500 M |
| Conductance |
50.00nS |
| Continuity beeper |
Yes |
| Battery/Fuse access |
Battery / Fuse |
| Peak |
250 μS |
| Elapse time clock |
Yes |
| Time of day clock |
Yes |
| Min-Max-Avg |
Yes |
| Frequency |
Yes |
| Duty Cycle |
0.01 % to 99.99 % |
| Pulse Width |
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
| Hold |
Yes |
| Isolated Optical Interface |
Yes |
| Auto/Touch Hold |
Yes |
| Reading memory |
Yes |
| Log to PC |
Yes |
| Interval/Event Logging |
Yes |
| Logging Memory |
Up to 10,000 readings |
| Resistance Low Ohm |
0.001 Ω to 50.000 Ω 10 mA source |
| LoZ |
Yes |
| Low Pass Filter |
Yes |
|
| Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Relative Humidity |
|
0% to 90% (0 °C - 37 °C) |
|
0% to 65% (37 °C - 45 °C), |
|
0 to 45 % (45 °C - 55 °C |
|
| Electromagnetic Compatability |
|
| Vibration |
|
Random vibration per MIL-PRF-28800f Class 2 |
|
| Shock |
|
1 meter drop per IEC/EN 61010-1 2nd edition |
|
| Safety Specifications |
| Overvoltage category |
|
CAT III 1000 V / CAT IV 600 V safety rated |
|
| Agency Approvals |
|
| Mechanical & General Specifications |
| Maximum voltage between any terminal and earth ground |
|
| Size |
|
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
|
| Weight |
|
| Battery Life |
|
100 minimum, 200 hours in logging mode |
|
| Battery type |
|
6 AA alkaline batteries, NEDA 15A IEC LR6 |
|
|